Basic Info.

Accuracy
>±1%
Main Application
Corrosive Liquid/Gas
Application
Energy Metering
Measuring Media
Gas
Measurement Object
Sf6 Gas
Transport Package
Plywood Case
Origin
China
HS Code
85389000

Product Description

Product Description

1.SGE-100M SF6 Gas-Density Relay


It is used to control and monitor the density of SF6 gas in sealed containers. It is used in SF6 high-voltage circuit breakers, medium-voltage switches, gas-insulated equipment (GIS), high-voltage cables, transformers and transformers, and is suitable for strong vibration and outdoor harsh external conditions.
PAPAMENTERS:
PAPAMENTERS:
Sealing performance1x10-8mbar./s(Helium test)
Electrocution capacityAC 250V 3A DC 250V 0.2A
Vibration resistance30m/s2
Impact resistance500m/s2
 
precisionClass 1.5 (at20°C) ambient temperature is -40C ~ +60C, accuracy level 2.5
Working environmentThe temperature is -40°C~+60C, and the relative temperature is 95%RH
Number of contactsTwo pairs or three pairs, normally open and normally closed at will
Controls the pressure value of the output(alarm, latch) can be specified by the user
Enclosure ratingIP65
 
Insulation properties2KV 1min
 

 
 
2.SGE-60M SF6 Gas-Density Relay


It is used to control and monitor the density of SF6 gas in sealed containers. This series of density relays are mainly used to monitor the density of SF6 gas in sealed containers, and can be widely used in SF6 circuit breakers, ring main units, gas filling cabinets, column switches, transformers and transformers, and are suitable for outdoor harsh external conditions.
PAPAMENTERS:
 
Sealing performance1x10-8mbar./s(Helium test)
Electrocution capacityAC 250V 3A DC 250V 0.2A
Vibration resistance20m/s2
Impact resistance300m/s2
 
PrecisionClass 1.5 (at20°C) ambient temperature is -40C ~ +60C, accuracy level 2.5
Working environmentThe temperature is -40°C~+60C, Relative temperature≤ 95%RH
Number of contactsTwo pairs or three pairs, normally open and normally closed at will
Controls the pressure value of the output(alarm, latch) can be specified by the user
Enclosure ratingIP65
 
Insulation properties2KV 1min
 


 
3.SGE-R100M Remote Density Relay (Microwater, Density)
PAPAMENTERS:
 
Leakage rate1x10-8mbar.l/s(Helium test)
Vibration resistance
 
20m/s2  Impact resistance:500m/s2
Measuring rangeDensity:-0.1-0.9MPa  Dew point:-80ºC~+20ºC
Precision
 
Density class 1(at20ºC)
When the ambient temperature is -40C~+60 °C,
 the accuracy class is 2.5: dew point± 3 °C
 
Working environment
 
The temperature is -40ºC~ +60ºC. The relative temperature is 95%RH
 
Micro switch contact, contact electrical parametersPower: 30VA; Maximum working voltage: 380V; Maximum current: 1A
weight4KG
Voltage-sensing elementBurton tube
Enclosure rating
 
IP55
Insulation properties
 
Insulation resistance: >100MQ (500V DC)
Insulation withstand voltage: 2000V, 50/60 Hz 1min



4.SGE-60B SF6 Gas-Density Meter

PAPAMENTERS:
Sealing performance1.0-2.0bar abs
PrecisionLevel 2.5
EnvironmentThe temperature is -40C~+60C (gaseous),  the relative humidity is ≤ 95%RH
Sealing performance1x10-8mbar./s(Helium test)
Outside diameterΦ60mm
Installation methodAxial or radial
5.SF6 Check Valve, GIS Three-way Valve
Key features
  1. The SF6 density relay can be verified or replaced without disassembling the SF6 density relay
  2. There is no need to remove the screws, and one person can operate independently. Convenient, labor-saving and time-saving
  3. It is convenient for on-site personnel to perform micrometer water and gas replenishment operation on the switch
  4. Damage to the sealing surface and sealing ring caused by disassembly is avoided
  5. High-quality stainless steel material, never rust, beautiful appearance
  6. Equipped with stainless steel rain cover, rain and sun protection, greatly improve the working reliability and service life of density relays
Illustrate
  1. All factory assemblies passed leak detection tests with ammonia mass spectrometer
  2. This assembly device can be used alone or with our SF6 gas density relay, and has reached more than 40 specifications and models.

Our Packing