• Sf6 12kv 630A Gas-Insulated Lbs/Pole-Mounted Load Break Switch
  • Sf6 12kv 630A Gas-Insulated Lbs/Pole-Mounted Load Break Switch
  • Sf6 12kv 630A Gas-Insulated Lbs/Pole-Mounted Load Break Switch
  • Sf6 12kv 630A Gas-Insulated Lbs/Pole-Mounted Load Break Switch
  • Sf6 12kv 630A Gas-Insulated Lbs/Pole-Mounted Load Break Switch
  • Sf6 12kv 630A Gas-Insulated Lbs/Pole-Mounted Load Break Switch

Sf6 12kv 630A Gas-Insulated Lbs/Pole-Mounted Load Break Switch

Type: Power
Structure: Pole-Mounted
Certification: ISO9001:2000
Form: Sf6 Gas Insulated
Operation Voltage: High Voltage
Application Range: Outdoor
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • FAQ
Overview

Basic Info.

Model NO.
RAF-12/630-20
Brand
Joyelectric
Insulating Medium
Sf6 Gas
Ambient Temperature
Max: +70ºC, Min-25ºC
Relative Humidity
100%
Altitude
<=3000m
Transport Package
Plywood Case
Origin
China
HS Code
85352100
Production Capacity
50000 Pieces/Year

Product Description

SF6 Gas-insulated LBS
RAF-12/630-20
Introduction
RAF-12/630 pole-mounted load switch is suitable for rated voltage 12kV, rated current 630A and 50/60Hz distribution system, and used for making and breaking disconnected, load current/overload current in the power system. It can automatically separate the fault section of distribution line when faults occur. The switch has manual, motor modes, it's easy and fast to install and the construction cost is low.

Ambient condition
Ambient temperature: Max: +70ºC, Min-25ºC.
Relative humidity: 100%
Altitude:  <=3000m.
Wind pressure:  <= 700 pa(equivalent to wind speed: 34m/s).
Seismic intensity: 8 degree.
Installation site : No danger of fire, explosion, chemical corrosion, frequently strenuous vibration.
Pollution grade : IV class.

Characteristics
SF6 is an insulation gas with excellent arc extinguishing performance;
Visible On/ OFF status, there are indicators on the operation side and the bottom of the device, it can be easily observed standing on the ground;
Durable, the switch shell is made of corrosion resistant material (304 stainless steel plate) and sprayed with protective paint to ensure a long service life (more than 30 years);
The main switch use fully sealed structure, not affected by the external environment;
Low leakage rate, less than 0.1%/year;
Mechanical stability of operating mechanism is high, mechanical life was designed as 10000 times;
All indicators use reflective materials, the state of witches can be accurately observed even in dark environment. 

Specifications

Standard IEC62271-103-2011
Number of phase  3  
Rated Voltage  12  kV
Impulse withstand voltage  85  kV
Power-frequency dry withstand voltage  42/48  kV
Power-frequency wet withstand voltage  34  kV
Frequency  50  Hz
Normal current  630  A
Short-time withstand current  20  kA
Peak withstand current  50  kA
Duration of short-circuit  3  s
Short-circuit making current   50  kA

InstallationSf6 12kv 630A Gas-Insulated Lbs/Pole-Mounted Load Break Switch
 
 

Thank you for your interest to our products.
For more information please kindly email us . We would like to reply you within one working day.

Sf6 12kv 630A Gas-Insulated Lbs/Pole-Mounted Load Break Switch
FAQ

 

Q: Could I have prices of your products?
A: Welcome. Please feel free to send us inquiry here. We will reply you within 24 hours
Q: Can l get a sample before the bulk order?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q: Can we print our logo/ company name on products?
A: Yes, of course, we accept OEM, then need you to provide brand authorization to us
Q:Do you accept product customization?
A: Yes, of course, please provide specific drawings or parameters, we will quote you after evaluation
Q: What is the lead time?
A: The lead time depends on the quantities ordered, generally within 7-20 days after receiving the payment.
Q: What is your Trade Terms?
A: We accept EXW, FOB, CIF, FCA, etc.
Q: What is your payment method?
A: We accept T/T, Western Union, Paypal, irrevocable L/C at sight, etc
Q: Do you inspect the finished products?
A: Yes, each step of production and finished products wil be came out inspection by Qc department before shipping. And we willprovide goods inspection reports for your reference before shipment
Q: How to solve the quality problems after sales?
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
1000000 RMB
Plant Area
501~1000 square meters